A-A-52498
2.9 Temperature. The floodlight shall conform to 2.3 and 2.4 when operated in temperatures of -65° to +160° Fahrenheit.
2.10 Identification marking. Identification markings shall be permanent and legible and shall include, as a minimum, the manufacturer’s identification code (CAGE) and part number, the part identification number PIN A52498-1, and the words “24 Volt” and “U.S.”.
2.11 Finish treatment. Cleaning, pretreating, priming and painting of the floodlight shall conform to an appropriate CARC paint system selected from Army drawing number 12369000 for external application. Unless otherwise specified (see 5.2), the color of the paint final top coat shall be green number 383.
3. QUALITY ASSURANCE PROVISIONS
3.1 Responsibility for inspection. The contractor is responsible for the performance of all inspections (examinations and tests).
3.2 Contractor certification. The contractor shall certify and maintain substantiating evidence that the product offered meets the salient characteristics of this CID and that the product conforms to the producer’s own drawings, specifications, workmanship standards, and quality assurance practices. Items with known defects shall not be submitted for Government acceptance. The Government reserves the right to require proof of such conformance prior to the first delivery and thereafter as may be otherwise provided for under the provisions of the contract.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business