2.4 Order of precedence. In the event of a conflict between the text of this document and the
references cited herein, the text of this document takes precedence. Nothing in this document, however,
supersedes applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection
(see 6.3) in accordance with 4.3.
3.2 Materials. Materials shall be as specified herein, on referenced drawings and in referenced
standards and specifications (see 4.6.1).
3.2.1 Recycled, virgin and reclaimed materials. There are no requirements for the exclusive use
of virgin materials. The use of recycled or reclaimed (recovered) materials is acceptable provided that all
other requirements of this specification are met (see 4.6.1 and 6.4.1).
3.3 Design and construction. Construction of the dome light shall be as specified on Drawing
7064671 and MS51073 (see 4.6.1 and 4.6.2).
3.3.1 Soldering. Soldering of electrical connections shall be in accordance with guideline
5 of MIL-HDBK -454. The solder shall conform to type RO of J-STD-004 (see 4.6.1 and 4.6.2).
3.3.2 Mechanical interlock. The dome light switch shall incorporate a mechanical interlock to
prevent the inadvertent energizing of any part of the light system except the blackout marker lights (see
4.6.2).
3.3.3 Dissimilar metals. The use of dissimilar metals shall be in accordance with MIL-STD-
889. Except where necessary to complete an electrical circuit, contact between dissimilar metals, which
would encourage galvanic action, shall be avoided. Where such contact is not necessary to complete an
electrical circuit, but is otherwise avoidable, parts shall be insulated (see 4.6.1 and 4.6.2).