MIL-DTL-3976F
3.4.4.2 Vibration resistance. The light assembly shall show no evidence of hours in
disintegration after exposure to vibration testing under power for not less than 2 each of 3
perpendicular axes for a total of 6 hours (see 4.6.4.2).
3.4.4.3 Shock resistance. The light assembly shall show no evidence of disintegration after
induced shocks of sawtooth waveform of 6 minutes duration and a peak value of 75 gravity units
(g) (see 4.6.4.3).
3.4.4.4 Waterproofness. The light assembly performance shall not be affected nor shall the
light assembly show signs of leakage during and after submersion while under power (see 4.6.4.4).
3.5 Painting. Unless otherwise specified (see 6.2), the external surface of the light
assembly shall be cleaned, primed, and finished in accordance with MIL-DTL-53072. The paint
topcoat shall conform to MIL-DTL-53039 or MIL-DTL-64159. Unless otherwise specified, the
color shall be lusterless camouflage forest green conforming to chip number 34083 of FED-STD-
595. When a lusterless desert tan color light assembly is specified in the contract or order, the chip
number shall be 33446 of FED-STD-595 (see 4.6.2).
3.6 Marking. Marking shall be in accordance with MIL-STD-130 and shall consist of the
MS part number and manufacturers identification (see 4.6.2).
3.7 Workmanship. For guidance on workmanship see guideline 9 of MIL-HDBK-454 (see
4.6.2).
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are
classified as follow:
a. First article inspection (see 4.3).
b. Conformance inspection (see 4.4).
c. Control tests (see 4.5).
4.2 Inspection conditions. The inspection requirements specified herein are classified as
follows:
a. Air temperature: 77 ± 18º F.
b. Relative humidity: Uncontrolled room ambient.
c. Atmospheric pressure: Site pressure.
4.3 First article inspection. When first article is required (see 3.1), first article inspection
shall be performed on four first article samples. Unless otherwise specified, first article inspection
shall include the inspections specified in table II (see 6.3.1 for first article inspection of spare parts).