MIL-DTL-58085C
3.8 Electromagnetic compatibility (EMC). The light shall meet the requirements of
MIL-STD-461. The enclosed case construction shall provide continuity of electrical
shielding. All mating surface shall be clean and carefully fitted to minimize radio
frequency impedance at joints, seams, and mounting surfaces.
3.9 Electrical power supply. The light shall be designed for continuous operation
when supplied with electrical power within the range of 20 to 30 volts (28 volts dc
nominal) and have characteristics as defined in MIL-STD-704.
3.9.1 Electrical power interface. The light shall maintain specified performance
when supplied with 28 volts dc (nominal) power having characteristics as defined in
MIL-STD-704 for category B equipment. In addition to the transient voltage
requirements of MIL-STD-704, the light shall not malfunction, or exhibit any
unacceptable response on any lead to or from the system, or any connecting lead when
subjected to transients of plus or minus 600 volts for 10 milliseconds. Also, the light
operation shall not degrade the aircraft electrical power supply characteristics beyond the
limits specified in MIL-STD-704.
3.10 Identification of light. Light shall be identified per MIL-STD-130.
3.11 Workmanship. The light, including all parts and accessories, shall be
constructed and finished to produce an item free from all defects which would affect
proper functioning. The item shall be free from burrs, sharp edges, metal chips, loose
solder, and other foreign material. Particular attention shall be given to the neatness and
thoroughness of soldering, wiring, marking, finish, alignment of parts, and tightness of
screw assemblies.
4. VERIFICATION
4.1 Classification of inspection: The inspection requirements specified herein are
classified as follows:
a. First article inspection (see 4.2).
b. Conformance inspection (see 4.3).
shall be subjected to all examinations and tests specified herein.
4.3 Conformance. Conformance examinations and tests shall consist of
examinations to determine compliance with this specification with respect to materials,
workmanship, and markings, and with the operational test specified in 4.5.2. Sampling
shall be in accordance with 4.4.
4.4 Sampling. A minimum of one light shall be selected at random from each 25 or
fraction thereof submitted for acceptance, and tested for flash rate as specified in 4.5.2.
A minimum of one light shall be selected at random from each 200 or fraction thereof
submitted for acceptance, and tested for light intensity as specified in 4.5.2.