MIL-DTL-14465F
3.7 Operating environment requirements. Each light assembly shall operate under the
following environmental conditions, without degradation in performance.
3.7.1 Temperature cycling. The light assembly shall withstand exposure to temperatures
as high as 85 degrees Celsius (°C) and as low as -55°C and to the thermoshock of alternate
exposures to these extremes (4.2.7.1).
3.7.2 Waterproofness. The light assembly shall evidence no leakage, operational or
mechanical damage during and after total submersion in a saline solution while supplied with 28
Vdc (4.2.7.2).
3.7.3 Vibration resistance. The light assembly shall be capable of withstanding the
vibration profile experienced in the variety of military tactical vehicles in which it is used
(see 4.2.7.3).
3.7.4 Shock resistance. The light assembly shall be capable of withstanding the
sawtooth wave shock pulses having a peak value of 30 gravity units (g) and a duration of 11
milliseconds (ms) (see 4.2.7.4).
3.7.5 Fungus resistance. The light assembly shall be resistant to conditions favorable to
fungal growth; during 28-30 degrees Celsius (°C) and not less than 85% relative humidity
(see 4.2.7.5).
3.7.6 Corrosion resistance. The light assembly shall be resistant to salt spray (fog) with
6.5-7.2 pH at 350C (see 4.2.7.6).
4. VERIFICATION
4.1 Classification of inspection. The inspection conditions specified herein are classified
as follows:
a. First article inspection.
b. Conformance Inspection (CI).
4.1.1 First article inspection. When specified (see 6.2), first article inspection shall be
performed on four initial production light assemblies as specified herein. Approval of the first
production units by the Government shall not relieve the contractor of the obligation to supply
assemblies that are fully representative of those inspected as a first article (see 6.4). First article
inspection shall consist of the examinations and tests as specified in table V.
4.1.1.1 Order of inspection. The first article inspection sequence shall be in the order
listed in table VI.
4.1.2 Conformance inspection. Unless otherwise specified (see 6.2), conformance
inspection shall include the examinations and tests specified in table V (see 6.5).
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business